There are no items in the shopping cart.
Condition:[NEW - Manufacturer Packed]
Promotion
gift Schneider Electric eCommerce Industrial Automation Program
Brand:SCHNEIDER ELECTRIC
Model:EZC100N3050
Code:EZC100N3050SCH
Weight:1.000 KG
MOQ:0
Number of Poles :3P
Current Rating:50A

More parameters>>

Quantity
On Hand    Group Stock    ETA Delivery   
Shipping time may vary.
VitalMRO rep will advise.


 ~ 

Product Filter

Clear All

Number of Poles
Current Rating
Range
Coil Voltage (AC)
Contact Voltage Rating
Breaking Capacity
  • Product
  • Attribute
  • Price
  • Add To Cart
  • Products Detail
  • Specification parameter
  • Products Q&A
Mobile phone purchase
goods qr code
Add To Cart
Price:
Quantity:
Inventory  PcsAccount Inventory  Pcs

Products Detail

Replacement Suggest:


Main
range of productEasyPact
product or component typeCircuit breaker
device short nameEasypact EZC100N
circuit breaker nameEasypact EZC100N
device applicationDistribution
poles description3P
protected poles description3t
network typeDC
AC
network frequency50/60 Hz
[In] rated current50 A at 40 °C
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
[Ue] rated operational voltage550 V AC 50/60 Hz conforming to IEC 60947-2
250 V DC conforming to IEC 60947-2
breaking capacity codeN
breaking capacity10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2
18 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
5 kA Icu at 125 V DC 1P conforming to IEC 60947-2
5 kA Icu at 250 V DC 2P conforming to IEC 60947-2
5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
9 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2
12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2
12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
2.5 kA at 125 V DC conforming to IEC 60947-2
2.5 kA at 250 V DC conforming to IEC 60947-2
2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2
7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
suitability for isolationYes conforming to IEC 60947-2
utilisation categoryCategory A
trip unit nameTM-D
trip unit technologyThermal-magnetic
trip unit rating50 A at 50 °C
protection typeOverload protection
Short-circuit protection
pollution degree3 conforming to IEC 60664-1
3 conforming to IEC 947-1

Complementary
control typeToggle
mounting modeFixed
mounting supportBackplate
upside connectionFront
downside connectionFront
mechanical durability8500 cycles
electrical durabilityCategory A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
connection pitch25 mm
local signallingPositive contact indication
neutral protection settingWithout protection
earth-leakage protectionWithout
height130 mm
width75 mm
depth60 mm
Environment
standardsGB/T 14048.2
EN/IEC 60947-2
JIS C8201-2-2
EN/IEC 60947-1
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
ambient air temperature for operation-25…70 °C
ambient air temperature for storage-35…85 °C
Packing Units
Unit Type of Package 1PCE
Package 1 Length14.0 cm
Number of Units in Package 11
Package 3 Width80.0 cm
Package 3 Weight160.228 kg
Package 2 Width30.0 cm
Package 2 Height15.0 cm
Package 2 Weight9.483 kg
Number of Units in Package 3192
Unit Type of Package 3P06
Package 3 Height77.0 cm
Package 3 Length60.0 cm
Package 1 Width9.4 cm
Package 1 Height7.2 cm
Package 1 Weight764.0 g
Number of Units in Package 212
Unit Type of Package 2S02
Package 2 Length40.0 cm


100 Rate %
I haven't set up the buyer's impression yet. Please wait with me~
No comment

User discussion circle

Subscribe to get more info
Compare

1

You can also continue adding

2

You can also continue adding

3

You can also continue adding

4

You can also continue adding